Flanders and Brussels regions (2014):
| Wall Insulation (W/m2.K) | 0.30 |
| Floor Insulation (W/m2.K) | 0.30 |
| Roof Insulation (W/m2.K) | 0.24 |
| Glazing U-Factor (W/m2.K) | 1.80 |
| Visible Light Transmittance** | 0.68 |
| Solar Heat Gain Coefficient** | 0.60 |
| Heating Efficiency | 0.95 |
| Cooling Efficiency** | 3 |
| Infiltration Rate (m3/m2.h) | 3.0 |
| Ventilation Rate (L/m3.s) | 0.3 |
| Appliance** | 3 |
| Lighting** | 4 |
| Daylight Response Efficiency** | 0 |
Walloon region (2014):
| Wall Insulation (W/m2.K) | 0.24 |
| Floor Insulation (W/m2.K) | 0.30 |
| Roof Insulation (W/m2.K) | 0.24 |
| Glazing U-Factor (W/m2.K) | 1.80 |
| Visible Light Transmittance** | 0.68 |
| Solar Heat Gain Coefficient** | 0.60 |
| Heating Efficiency** | 0.95 |
| Cooling Efficiency** | 3 |
| Infiltration Rate (m3/m2.h) | 3.0 |
| Ventilation Rate (L/m3.s) | 0.3 |
| Appliance** | 3 |
| Lighting** | 4 |
| Daylight Response Efficiency** | 0 |
** typical values used, not specified by regulations