Target Energy Consumption (kWh/m2.year)
| Building Type | |
| Dwellings (kWh/m2.year) | 60 |
| Other (kWh/m2.year) | 100 |
Plugin Values
| Wall Insulation (W/m2.K) | 0.21 | |
| Floor Insulation (W/m2.K) | 0.21 | |
| Roof Insulation (W/m2.K) |
Flat: 0.20 |
Pitched: 0.16 |
| Glazing U-Factor (W/m2.K) | 1.60 | |
| Visible Light Transmittance | 0.80 | |
| Solar Heat Gain Coefficient | 0.72 | |
| Heating Efficiency | 0.90 | |
| Cooling Efficiency** | 3 | |
| Infiltration Rate (m3/m2.h) | 5 | |
| Ventilation Rate (L/m3.s) | 1.39 | |
| Appliance** | 4 | |
| Lighting** | 4 | |
| Daylight Response Efficiency** | 0 |
Web App Values
Envelope Parameters
| Wall Insulation (W/m2.K) | 0.21 | |
| Floor Insulation (W/m2.K) | 0.21 | |
| Roof Insulation (W/m2.K) |
Flat: 0.2 |
Pitched: 0.16 |
| Glazing U-Factor (W/m2.K) | 1.60 | |
| Solar Heat Gain Coefficient | 0.72 |
HVAC Parameters
| Design Fan Power (kW.s/m3)** |
CAV: 1.8 |
VAV: 2.1 |
||
| Heating COP |
0.90 |
|||
| Cooling COP** | 3 | |||
| Ventilation Rate (L/m3.s) | 1.39 | |||
** Typical value inputted as no value provided
For more information on Part L and Sefaira see here.